Boyd Pollard
06/28/2024 · Middle School
7. Encuéntrese la regulación de un generador de ca que tiene un voltaje a plena carga de 2600 V y un voltaje sin carga de 3310 V con un factor de potencia de \( 85 \% \). Con un FP de la unidad, ¿será la regulación porcentual mayor, menor o igual que con el FP atrasado \( 85 \% \) ?.
Upstudy ThothAI Solution
Tutor-Verified Answer
Quick Answer
La regulación porcentual es aproximadamente \( 27.31\% \). Con un FP de unidad, la regulación es menor que con un FP de \( 85\% \).